4. For the Service Technician
4.5.2 Start-up
The auger conveyor and the feed can be selected on the Start-up level with the arrow buttons, then confirmed
or selected using the Choose button. A self-test is started at the end of the start-up.
Fig. 72
Start-up
Auger conveyor
Feed
Choose Back
Auger conveyor
The auger conveyor can be switched on for 6 minutes.
Feed
Depending on the set feed system, the feed and each probe incl. purging can
be started up.
4.5.3 Actuator test
The following actuators can be selected with the arrow buttons, then confirmed and started using the Choose
button. The actuators are switched off again after 1 minute. A self-test is started at the end of an actuator test.
Fig. 73
Induced draught fan
Auger conveyor
Ash removal
Ignition element
Ash removal
Heating surf. cleaning
Choose Back
– Induced draught fan
– Auger conveyor
– Ash removal
– Ignition element
– Ash removal
– Heating surface cleaning
– Suction turbine
– Probe switching
– Air intake/exh. flap
– Boiler pump
Fig. 74
Suction turbine
Probe switching
Air intake/exh. flap
Boiler pump
Choose Back
4.5.4 Settings
This sub-menu contains the following settings:
– Install display module
– Language selection
– Temperature format
– Time format
– Date format
Fig. 75
Install display module
Language selection
Temperature format
Time format
Date format
Choose Back