2. Operation
5s
RESET
Fig. 78
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Time profile ash compression
Choose Back
Confirm the selected sub-menu “Feed operating mode” by
pressing the Choose button – Fig. 78.
The factory setting for „Feed operating mode“ is „switched
off“.
Without time control: Select this if the feed noise (suction
turbine) is not audible or intrusive in the living area. This
mode guarantees the fewest possible feeds because the
reserve supply container is always „run to empty“.
Functional description: The pellet feed is automatically
switched on if required at any time.
With start time: Select this if you want the feed to start at
the same time every day.
Functional description: The reserve supply container is
filled every day if required at the set time (see page 35).
Interim fills are also performed if the filling amount is
not sufficient for 24 hours.
With enable time: Select this if the feed noise (suction tur-
bine) is audible or intrusive in the living area.
Functional description: The pellet feed is enabled during
a time period that can be set (see page 33) and is au-
tomatically started at this time if required. The reserve
supply container is fully refilled at the end of the enable
time, if required.
5s
RESET
Fig. 79
Feed operating mode
With enable time
With start time
Without time control
Switched off
Choose Back
Use the arrow buttons to select the required sub-menu
item – Fig. 79.
The changed „Feed operating mode is saved by pressing
the save button Fig. 80. The display shows „Parameter is
saved“ for a few seconds (Fig. 81) and then changes back to
the previous level – Fig. 82.
The menu item or sub-menu item is exited by pressing the
Back button (Fig. 82) or after a delay of 45 seconds.
5s
RESET
Fig. 80
Feed operating mode
With enable time
With start time
Without time control
Switched off
Choose Back
Fig. 81
Parameter is saved
(Symbol animiert)
5s
RESET
Fig. 82
Boiler cleaning
Time
Feed operating mode
Time profile feed
Probe switching
Time profile ash compression
Choose Back
Tip!
A complete fill sucks in about 25 kg of pellets.
Even if more pellets are required during the
blocked time, there is no automatic fill and
the FireWIN switches off (fault message 381).
Therefore, do not select a lock-out time that
is too long.
Burning duration with 25 kg pellets
FireWIN Burning duration at nominal output
FW 090 approx. 12,5 Std.
FW 120 approx. 10 Std.
Note!
It is only ever possible to select one menu
item at a time. The Time profile feed“ corre-
sponding to this selected menu item can then
be set in section 2.8.1.4.