15) For the running-in of one cylinder, you can temporarily decrease its load. See
step a) and step b):
a) In the remote control, get in the MAINTENANCE SETTINGS in the ADJUST
page (see 4002−3, User parameters and Maintenance Settings,
paragraph 1.2).
b) In the Inj. correction factor page, set the applicable value.
2. Fuel
For running-in, use heavy fuel oil (HFO). Make sure that the fuel has the correct
treatment and viscosity (i.e. heated to the correct temperature).
3. Cylinder Lubricating Oil
For usual operation and running-in conditions, use cylinder lubricating oil that has a
high-alkaline base number (BN) (see 0750−1 Cylinder Lubricating Oil, paragraph 3)
when HFO with a high sulphur content is used.
Running-in of New Cylinder Liners and Piston Rings
2017−08