Operation4003−1/A1
Winterthur Gas & Diesel Ltd.
6/ 12
4.5 Automatic Filter
1) Make sure that control air is available at the automatic filter.
2) In the oil pipe upstream and downstream of the automatic filter, make sure that
stop valves 4.37 and 4.80 are open.
3) In the pressure compensating pipe near the oil outlet, make sure that the stop
valve is closed.
4) Make sure that there is a power supply at the control box E92. Set the main
switch to on.
5) Bring selector switch in the control box to ’Adjust’ ( ll ). On the display the
parameters can be adjusted.
6) To adjust the settings to those given in Table 4 (and for other parameter settings),
refer to the instructions given in the documentation of the control box E92 (Boll &
Kirch electronic controller Type 2200).
Table 4: Adjustable Parameters Automatic Filter
Function
Parameter Adjustment
Flushing interval in hours P2 1
Flushing interval in minutes P3 0
Flushing time in seconds P4 20
Differential pressure (alarm) P8 ON
Note: See also the instructions of the automatic filter manufacturer.
7) On the control box E92, push the center button on the keypad to start a flush
cycle of 20 seconds.
8) Make sure that the motor of the rotation device turns in the correct direction
(clockwise when seen from the top).
2017−08
Engine Control