1128500 WPC 2000 User Manual
I-2 Index
DSV (Dual Safety Valve)
faults
, 5-17, 5-21
installing and wiring,2-9
testing wiring,2-60
dual operator stations
labelling
,2-18
wiring,2-17
–E–
E series faults, responding to,5-5
emergency-stop button (operator station)
location
,1-3
testing emergency-stop circuit in continuous
mode
,3-39
testing emergency-stop circuit in inch mode,2-61
enclosure (WPC 2000)
components
,1-1
mounting and wiring,2-6
errors. See faults (WPC 2000)
–F–
F series faults, responding to,5-5
faults (WPC 2000)
brake monitor faults
,5-3
component failures,5-12
customized status codes,5-12
DSV and lockout relay failures,5-17
emergency-stop circuit driver failure,5-15
input buffer test failures,5-11
internal memory failures,5-21
internal timing input failures,5-18
inter-processor failures,5-11
light curtain faults,5-14
loss of rotation,5-18
operational faults,5-7
overrun limit switch faults,5-19
resolver faults,5-6
responding to,5-2
Shadow light curtain input faults,5-16
testing for in continuous mode,3-40
testing for in inch mode,2-61
top-stop and overrun setting faults,5-19
top-stop circuit driver failure,5-15
features, WPC 2000,1-5
firmware (WPC 2000), installing revised,2-49
foot switch
enabling foot trip or foot control
,3-27
operating the press in continuous foot,4-18
operating the press in single-stroke foot,4-15
testing,3-54
wiring,2-42
–H–
H faults, responding to,5-5
Herion DSV, installing and wiring,2-11
–I–
inch mode
operating the press in dead motor inch
,4-10
operating the press in micro-inch,4-10
operating the press in top-stop bypass,4-9
operating the press in top-stop in inch,4-9
indicator segment LEDs, location,1-4
inputs, user. See user inputs
interlocks. See user inputs
interrupted stroke
location of interrupted stroke LED
,1-5
responding to,4-3
setting auxiliary output 1 response to,3-31
–J–
jumper settings, Shadow VII and Shadow 8,2-19
–L–
labels, dual operator station,2-18
LEDs
brake warning LED
,4-3
digital readout,1-4
indicator segments,1-4
interrupted stroke LED,4-3
LED indicator map, 3-37, 3-38
locations on WPC 2000 display,1-4
observing state in final checkout tests,3-36
light curtain(s)
calculating the safety distance for
,3-20
enabling light curtain break mode,3-27
faults, 5-14, 5-16
increasing the safety distance for floating or
blanking windows
,3-24
installation requirements, 2-13, 2-18
installing non-Shadow light curtains,2-19
jumper settings (Shadow VII and Shadow
8)
,2-19
object sensitivity,3-21
response times,3-21
testing safeguarding devices,2-59
testing Shadow light curtains,3-41
lockout
clearing lockout message
,5-3
lockout relay faults,5-17
wiring lockout relay,2-30
–M–
magnet (overrun limit sensor), mounting,3-9
micro-inch
operating the press in
,4-10
setting micro-inch time,3-25
wiring,2-33
micro-inch key switch
installing and wiring (display board kit)
,2-58
installing and wiring (panel mount),2-55
location and function,1-2

Table of Contents