WPC 2000 User Manual 1128500
Index I-3
mode select key switch
installing and wiring (display board kit)
,2-58
installing and wiring (panel mount),2-55
location and function,1-1
mounting dimensions. See dimensions (mounting/
cutout)
mounting plate (WPC 2000), installing
,2-51
multiple operator stations. See operator station(s)
mute lamp
installing and wiring (display board kit)
,2-57
location and function,1-5
–N–
ninety degree (90°) stop-time test,
performing
, 3-17, 3-18
noise (electrical), reducing,2-39
–O–
object sensitivity, Shadow light curtains,3-21
Occupational Safety and Health Administration
(OSHA)
extracts of regulations
,A-1
safety distance formula,3-23
one-hand control
enabling light curtain break mode
,3-27
mounting,2-44
single-stroke operation,4-13
testing,3-56
using in "light curtain break" mode, 2-43, 4-13
wiring to WPC 2000,2-45
one-hand mode, single-stroke operation,4-12
operating modes
running the press in bar mode
,4-19
running the press in continuous,4-17
running the press in inch,4-8
running the press in single-stroke,4-11
operator station(s)
anti-repeat test
,3-49
anti-tiedown test,3-48
building your own operator station,2-17, B-1
checking wiring of pre-wired operator
station
,2-13
components,1-3
installing multiple operator stations,2-17
labelling dual operator stations,2-18
mounting and wiring,2-12
setting concurrent time for multiple op.
stations
,3-33
setting palm time for one or two op.
stations
,3-33
setting prior act time for automatic modes,3-29
testing emergency-stop button in continuous
mode
,3-39
testing emergency-stop button in inch mode,2-61
testing top-stop button,3-40
using multiple operator stations, 2-17, 4-20
wiring dual operator stations,2-17
wiring unwired operator station,2-16
option switches. See press option switches, setting
outputs. See auxiliary outputs
overrun limit switch
faults
, 5-19, 5-20
mounting sensor magnet,3-9
mounting sensor switch,2-26
planning installation,2-26
setting top-stop "on" angle, 3-6, 3-26
wiring sensor switch,2-27
–P–
palm time, setting for one or two op. stations,3-33
panel mount (WPC 2000)
installing selector switches
,2-54
mounting in enclosure or console,2-52
PC boards, location of components
WPC 2000 display board
,2-34
WPC 2000 main processor board (left
mount)
,2-24
WPC 2000 main processor board (right/center
mount)
,2-23
power supply
requirements
,1-8
testing,3-41
Precision Metalforming Association (PMA),
interpretation of OSHA regulations
,A-1
preset. See counter
press option switches, setting
,3-26
pressure switch. See air pressure switch
prior act time, setting for automatic modes
,3-29
–R–
remote reset switch, wiring,2-35
reset/select button
installing and wiring (display board kit)
,2-57
location and function,1-5
resolver
checking direction of rotation
,2-25
connecting multiple controls to,2-32
faults,5-6
mounting,2-21
wiring,2-22
zeroing,3-4
response times, Shadow light curtains,3-21
Ross DSV
installing and wiring
,2-10
resetting faults (DM2),5-21
–S–
safeguarding devices, testing,2-59
safety distance
calculating with ANSI formula
,3-21
calculating with OSHA formula,3-23
increasing for floating or blanking windows,3-24
selector switches
installing with display board kit
,2-55
installing with panel mount,2-54
location,1-2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wintriss wpc 2000 and is the answer not in the manual?

Wintriss wpc 2000 Specifications

General IconGeneral
BrandWintriss
Modelwpc 2000
CategoryController