200 Operating Manual for XDC Series Power Supply
SCPI Command Reference
SCPI Command Summary
Table B.2Readback Commands
Save Default Settings
*SDS
[:]SYSTem[<channel>]:SAVE:DEFault <setting_location>
Save the factory default settings. N/A
Query Service Request
Enable
*SRE?
[:]STATus[<channel>]:SREQuest:ENABle?
Query the Service Request Enable Register
bits.
N/A
Service Request Enable
*SRE
[:]STATus[<channel>]:SREQuest:ENABle <status-enable>
Set the Service Request Enable Register
bits.
N/A
Read Status Byte
*STB?
[:]STATus[<channel>]:SBYTe[EVENt]?
Read the status byte and Master Summary
Status bit.
N/A
Trigger
*TRG
Trigger commands. Analogous to the IEEE
488.1 defined Group Execute Trigger
interface message. See IEEE 488.2 section
6.1.4.2.5
N/A
Self-Test Query
*TST?
[:]SYSTem[<channel>]:TEST?
Internal self-test and responds indicating
whether or not the device completed the
self-test without any detected errors.
N/A
Wait To Continue
*WAI
[:]SYSTem[<channel>]:WAIT
Prevents the device from executing any
further commands or queries until the
no-operation-pending flag is TRUE.(*OPC?)
N/A
Function
SCPI Command
Description Query
Read Output Current
[:]MEASure[<channel>][:SCALar]:CURRent[:DC]?
Read output current N/A
Read Output Power
[:]MEASure[<channel>][:SCALar]:POWer[:DC]?
Read output power N/A
Read Output Voltage
[:]MEASure[<channel>][:SCALar][:VOLTage][:DC]?
Read output voltage N/A