16 Model Specifications
Please note that three versions are to be distinguished:
Standard version
High Performance version (H-version)
High Performance version (H-version) in IP65 version
The H-version is characterized by the following enhanced features amongst others:
The housing face plate is not IR transparent film, but a mechanical, robust silicon
wafer disc specially developed for this application, and characterized by its high
permeability to IR radiation, as well as its resistance to sabotage.
Because of this precise optic greater nominal range compared to standard types can
be achieved.
H versions include a built-in heating mechanism.
Because of this heating, applicability extends to harsh climatic environments. The
detectors can be used in spite of variations in temperature, because the resulting air
condensation, which could cause signal attenuation due to water droplets building up
on the face plate or the mirror, is counteracted.
The following specifiations are valid for all ADPRO PRO-PIR detector models:
SPECIFICATIONS All ADPRO PRO-PIR Detectors
Spectral response 8-14μm, double filter
Speed ranges for detection 0,2 – 5,0 m/s
Sensitivity adjustments
(% per default setting)
DIP-
switch
: 40%, 75% 100%
Sensitivity or Range, depending on model, see section 16.1
and 16.2.
PRO
software
: 20 - 140%
depending on models:
all single-sensor detectors (18, 30, 40, 45): 20-140%
all multi-sensor detectors (51, 85, 100, 250): 50-150%
Window Standard version : PE-Filter, IR transmissive
High-Performance
H-versions
: Silicon wafer
Vandalism detection of housing Tilt and housing opening detection (NC contact 30V/100 mA)
Alarm indication Internal LED
Alarm outputs
PRO-xxx
1x relais SPST 30V
DC
@ 100 mA max.
1x open collector 30V
DC
@ 50 mA max.
PRO-250H
1x relais SPST 30VDC @ 100 mA max.
1x open-collektor 30VDC @ 50 mA max.
3x optocoupler outputs for one each alarm zone
(short/medium/long)
Communication RS-485, 9,6kBit/s
Temperature compensation Full compensation over the whole operating temperat. range
Supply voltage 10,5 - 30V
DC
, 24V
AC
±15% (w/o heater)
Current consumption 18 mA @ 12V
DC
, 14 mA @ 24V
DC
Power consumption of heater 2W / 176 mA @ 12 V
DC
and -40°C (H-versions only)
Operating temperature Standard versions : -20º up to +60°C