Maintenance and inspection
7 - 41
7 Maintenance and inspection
7.1 Periodic inspection
DANGER!
Death from electrical shock, risk of injury and fire due to short circuit
 Do not touch the cooling fan or other equipment while the power is turned ON.
Carry out the following inspections.
Components Inspection Method Inspection fre-
quency
Robot controller Check that the casing is com-
pletely closed and not dam-
aged.
Visual inspec-
tion
Daily
Check for gaps or damage to 
the sealed construction.
Visual inspec-
tion
Monthly
Power cable Check for damage and deterio-
ration of leads.
Visual inspec-
tion
as required
Interior circulation 
fan and backside 
duct fan.
Check the function (while power 
ON).
Visual inspec-
tion
as required
Emergency stop 
button
Check the function (while servo 
power ON).
By pressing 
the keys
Before the robot is 
put into operation.
Enabeling device Check the function (in teach 
mode).
as required
Battery Confirm battery alarm or  mes-
sage is displayed or not.
as required
Power supply Check power supply voltage is 
normal
Visual inspec-
tion
as required