User Constant Tables
5-
25
Torque Compensation: C4
User constants for torque compensation are shown in the following table.
* The factory setting will change when the control method is changed. The open-loop vector 1 factory settings are given.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
C4-01
Torque com-
pensation
gain
Sets torque compensation
gain as a ratio.
Usually setting is not neces-
sary.
Adjust in the following cir-
cumstances:
When the cable is long;
increase the set value.
When the motor capacity is
smaller than the Inverter
capacity (Max. applicable
motor capacity), increase
the set values.
When the motor is oscillat-
ing, decrease the set val-
ues.
Adjust the output current
range at minimum speed rota-
tion so that it does not exceed
the Inverter rated output cur-
rent.
Do not alter the torque com-
pensation gain from its
default (1.00) when using the
open-loop vector 1 control
method.
0.00 to
2.50
1.00 Yes A A A No No 215H
4-29
6-39
Torq Comp
Gain
C4-02
Torque com-
pensation
primary
delay time
constant
The torque compensation
delay time is set in ms units.
Usually setting is not neces-
sary.
Adjust in the following cir-
cumstances:
When the motor is oscillat-
ing, increase the set values.
When the responsiveness
of the motor is low,
decrease the set values.
0 to
10000
20 ms
*
No A A A No No 216H
4-29
6-39
Torq Comp
Time
C4-03
Forward
starting
torque
Sets the forward starting
torque as a percentage of the
motor rated torque.
0.0 to
200.0
0.0% No No No A No No 217H
F
TorqCmp@
start
C4-04
Reverse
starting
torque
Sets the reverse starting
torque as a percentage of the
motor rated torque.
-200.0
to 0.0
0.0% No No No A No No 218H
R
TorqCmp@
start
C4-05
Starting
torque time
constant
Sets the delay time in ms for
starting torque. The filter is
disabled if the time is set to 0
to 4 ms.
0 to
200
10 ms No No No A No No 219H
TorqCmp
DelayT
TOE-S616-60.1.book 25 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals