User Constant Tables
5-75
Multi-function Selections: o2
User constants for Digital Operator key functions are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
o2-01
LOCAL/
REMOTE
key enable/
disable
Sets the Digital Operator
Local/Remote Key
0: Disabled
1: Enabled (Switches
between the Digital
Operator and the constant
settings.)
0 or 1 1 No A A A A A 505H
6-148
Local/
Remote Key
o2-02
STOP key
during con-
trol circuit
terminal
operation
Sets the Stop Key in the run
mode.
0: Disabled (When the Run
Command is issued from
and external terminal, the
Stop Key is disabled.)
1: Enabled (Effective even
during run.)
0 or 1 1 No A A A A A 506H
6-149
Oper STOP
Key
o2-03
User con-
stant initial
value
Clears or stores user initial
values.
0: Stores/not set
1: Begins storing (Records
the set constants as user
initial values.)
2: All clear (Clears all
recorded user initial
values)
When the set constants are
recorded as user initial val-
ues, 1110 will be set in A1-
03.
0 to 2 0 No A A A A A 507H
6-149
User Defaults
o2-04
kVA selection
Do not set. 0 to FF
0
*1
No A A A A A 508H -
Inverter
Model #
o2-05
Frequency
reference set-
ting method
selection
When the frequency reference
is set on the Digital Operator
frequency reference monitor,
sets whether the Enter Key is
necessary.
0: Enter Key needed
1: Enter Key not needed
When set to 1, the Inverter
accepts the frequency refer-
ence without Enter Key oper-
ation.
0 or 1 0 No A A A A A 509H
6-149
Operator
M.O.P.
o2-06
Operation
selection
when digital
operator is
disconnected
Sets the operation when the
Digital Operator is discon-
nected.
0: Disabled (Operation
continues even if the
Digital Operator is
disconnected.)
1: Enabled (OPR is detected
at Digital Operator
disconnection. Inverter
output is cut off, and fault
contact is operated.)
0 or 1 0 No A A A A A 50AH -
Oper Detec-
tion
o2-07
Cumulative
operation
time setting
Sets the cumulative operation
time in hour units.
Operation time is calculated
from the set values.
0 to
65535
0 hr No A A A A A 50BH
6-149
Elapsed Time
Set