6-28
Adjusting Frequency References
This section explains methods of adjusting frequency references.
 Adjusting Analog Frequency References
Gain and bias are among the constants used to adjust analog inputs.
Related Constants
Con-
stant 
Number
Name
Description
Setting 
Range
Factory 
Setting
Change 
during 
Opera-
tion
Control Methods
MEMO
BUS
 Regis-
ter
Display
V/f
V/f 
with 
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
H3-01
Signal level 
selection (ter-
minal A1)
0: 0 to 10 V 
1: -10 to 10 V
[11-bit + polarity (positive/
negative) input]
0 or 1 0 No A A A A A 410H
Term A1 Signal
H3-02
Gain (terminal 
A1)
Sets the frequency when 10 V is 
input, as a percentage of the maxi-
mum output frequency.
0.0 to 
1000.0
100.0
%
YesAAAAA411H
Terminal A1 
Gain
H3-03
Bias (terminal 
A1)
Sets the frequency when 0 V is 
input, as a percentage of the maxi-
mum frequency.
-100.0
 to 
+100.0
0.0% Yes A A A A A 412H
Terminal A1 
Bias
H3-04
Signal level 
selection (ter-
minal A3)
0: 0 to 10 V
1: -10 to 10 V
 [11-bit + polarity (positive/
negative) input]
0 or 1 0 No A A A A A 413H
Term A3 Signal
H3-05
Multi-function 
analog input 
(terminal A3) 
function selec-
tion
Select multi-function analog input 
function for terminal A3.
0 to 1F 2 No A A A A A 414H
Terminal A3 
Sel
H3-06
Gain (terminal 
A3)
Sets the input gain (level) when 
10 V is input.
Set according to the 100% value 
selected from H3-05.
0.0 to 
1000.0
100.0
%
Yes A A A A A 415H
Terminal A3 
Gain
H3-07
Bias (terminal 
A3)
Sets the input gain (level) when 
0 V is input.
Set according to the 100% value 
selected from H3-05.
-100.0 
to 
+100.0
0.0% Yes A A A A A 416H
Terminal A3 
Bias
H3-08
Signal level 
selection 
(terminal A2)
0: 0 to 10 V
1: -10 to 10 V
2: 4 to 20 mA (9-bit input).
Switch current and voltage input 
using the switch on the control 
panel.
0 to 2 2 No A A A A A 417H
Term A2 Signal