EasyManua.ls Logo

YASKAWA Varispeed G7 - Using a Digital Reference Board

YASKAWA Varispeed G7
499 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
6-165
Related Constants
Setting Precautions
Always set b1-01 (Reference selection) to 1 (control circuit terminal) when using the AI-14B for three chan-
nels of independent inputs. When this is done, H1-01 to H1-10 (multi-function contact inputs) cannot be set to
2 (Option/Inverter selection).
Using a Digital Reference Board
When using a DI-08 or DI-16H2 Digital Reference Board, set b1-01 (Reference selection) to 3 (Option board).
The DI-16H2 can be used to set a frequency using a 16-bit digital reference. The DI-08 can be used to set a
frequency using a 8-bit digital reference.
Related Constants
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
F2-01
Bi-polar or uni-
polar input
selection
Sets the functions for channel 1 to
3 that are effective when the AI-
14B Analog Reference Board is
used.
0: 3-channel individual (Chan-
nel 1: terminal A1, Channel 2:
terminal A2, Channel 3: termi-
nal A3)
1: 3-channel addition (Addition
values are the frequency refer-
ence)
When set to 0, select 1 for b1-01.
In this case the multi-function
input “Option/Inverter selection”
cannot be used.
0 or 1 0 No A A A A A
38FH
AI-14 Input Sel
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
F3-01
Digital input
option
Sets the Digital Reference Board
input method.
0: BCD 1% unit
1: BCD 0.1% unit
2: BCD 0.01% unit
3: BCD 1 Hz unit
4: BCD 0.1 Hz unit
5: BCD 0.01 Hz unit
6: BCD special setting (5-digit
input)
7: Binary input
6 is only effective when the DI-
16H2 is used.
When o1-03 is set to 2 or higher,
the input will be BCD, and the
units will change to the o1-03 set-
ting.
0 to 7 0 No A A A A A 390H
DI Input

Table of Contents

Other manuals for YASKAWA Varispeed G7

Related product manuals