5-86
Fault History: U3
User constants for the error log are shown in the following table.
Note The following errors are not recorded in the error log: CPF00, 01, 02, 03, UV1, and UV2.
Con-
stant
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MEMO-
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
-loop
Vec-
tor
2
U3-01
Most recent
fault
The error contents of 1st
previous fault.
(Cannot be output.)
-AAAAA90H
Last Fault
U3-02
Second most
recent fault
The error contents of 2nd
previous fault.
-AAAAA91H
Fault Mes-
sage 2
U3-03
Third most
recent fault
The error contents of 3rd
previous fault.
-AAAAA92H
Fault Mes-
sage 3
U3-04
Fourth/oldest
fault
The error contents of 4th
previous fault.
-AAAAA93H
Fault Mes-
sage 4
U3-05
Cumulative
operation
time at fault
The total operating time
when the 1st previous fault
occurred.
1
hr
AAAAA94H
Elapsed Time
1
U3-06
Accumulated
time of sec-
ond fault
The total operating time
when the 2nd previous fault
occurred.
1
hr
AAAAA95H
Elapsed Time
2
U3-07
Accumulated
time of third
fault
The total operating time
when the 3rd previous fault
occurred.
1
hr
AAAAA96H
Elapsed Time
3
U3-08
Accumulated
time of
fourth/oldest
fault
The total operating time
when the 4th previous fault
occurred.
1
hr
AAAAA97H
Elapsed Time
4

Table of Contents

Other manuals for YASKAWA Varispeed G7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 and is the answer not in the manual?

YASKAWA Varispeed G7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7
CategoryInverter
LanguageEnglish

Related product manuals