5-88
* 1. The settings will be 0.05 (Flux vector)/1.00 (open-loop vector) for Inverters of 45kW or larger.
* 2. The settings shown are for 200 V Class Inverters. The values will double for 400 V Class Inverters.
* 3. Settings vary as shown in the following tables depending on the Inverter capacity and E1-03.
* 4. The setting range for open-loop vector 2 control is 0 to 66.0 (0 to 132.0 for PRG: 103).
* 5. 1000 ms for Inverters of 200 V Class 30 to 110 kW and 400 V Class 55 to 300 kW.
200 V and 400 V Class Inverters of 0.4 to 1.5 kW
* The setting shown are for 200 V Class Inverters. The values will double for 400 V Class Inverters.
200 V and 400 V Class Inverters of 2.2 to 45 kW
* The setting shown are for 200 V Class Inverters. The values will double for 400 V Class Inverters.
E1-09
E3-07
Min. output frequency (FMIN)
0.0 to 400.0 0.1 Hz
1.5
*3
1.5
*3
0.5 0.0 0.3
Min Frequency
E1-10
E3-08
Min. output frequency voltage (VMIN)
*2
0.0 to 255.0
(0.0 to 510.0)
0.1 V
9.0
*3
9.0
*3
2.0 0.0 1.0
Min Voltage
F1-09
Overspeed detection delay time
0.0 to 2.0 0.1 s - 1.0 - 0.0 0.0
PG Overspd Time
N5-01
Feedforward control selection
0, 1 1 - - - 0 1
Feedfoward Sel
Con-
stant
Num-
ber
Unit
Factory Setting
Open
Loop
Vector
Con-
trol
1
Open
Loop
Vector
Con-
trol
2
Flux
Vector
Con-
trol
E1-03
-0123456789ABCDEF
E1-04 Hz
50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0 60.0 60.0 60.0
E1-05
*
V
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
E1-06 Hz
50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 0.0
E1-07 Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0.0
E1-08
*
V
15.0 15.0 15.0 15.0 35.0 50.0 35.0 50.0 19.0 24.0 19.0 24.0 15.0 15.0 15.0 15.0 11.0 13.3 0.0
E1-09 Hz
1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.3 0.0
E1-10
*
V
9.0 9.0 9.0 9.0 8.0 9.0 8.0 9.0 11.0 13.0 11.0 15.0 9.0 9.0 9.0 9.0 2.0 1.3 0.0
Con-
stant
Num-
ber
Unit
Factory Setting
Open
Loop
Vector
Con-
trol
1
Open
Loop
Vector
Con-
trol
2
Flux
Vector
Con-
trol
E1-03
-0123456789ABCDEF
E1-04 Hz
50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0 60.0 60.0 60.0
E1-05
*
V
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
E1-06 Hz
50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 0.0
E1-07 Hz 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0.0
E1-08
*
V
14.0 14.0 14.0 14.0 35.0 50.0 35.0 50.0 18.0 23.0 18.0 23.0 14.0 14.0 14.0 14.0 11.0 13.3 0.0
E1-09 Hz
1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.3 0.0
E1-10
*
V
7.0 7.0 7.0 7.0 6.0 7.0 6.0 7.0 9.0 11.0 9.0 13.0 7.0 7.0 7.0 7.0 2.0 1.3 0.0
Con-
stant
Number
Name
Setting Range Unit
Factory Setting
Display
V/f
Control
V/f with
PG
Open-
loop
Vector
1
Flux
Vector
Open
Loop
Vector
2