Setting Inverter Input Voltage
Set the Inverter input voltage correctly in E1-01 to match the power supply voltage. This set value will be the
standard value for the protection function and similar functions.
The overvoltage detection level (OV) and the braking transistor operation level (BTR) vary depending on the
input voltage as shown in the following table.
* These are values of operation levels for braking transistors built in Inverters of 0.4 to 15 kW. Refer to FOR VARISPEED-600 SERIES INVERTER BRAK-
ING UNIT BRAKING RESISTOR UNIT INSTRUCTIONS (TOBPC720600000) for operation levels for separately-installed type Braking Resistor Units.
If selecting a fixed V/f pattern (E1-03 = 0 to E) in V/f control the values of the max. voltage (E1-05), the mid.
Output frequency voltage (E1-08), and the min. output frequency voltage (E1-10) will change if the value for
the input voltage setting (E1-01) is changed.
E1-11
Mid. output
frequency 2
Set only to fine-adjust V/f for the
output range. Normally, this setting
is not required.
0.0 to
400.0
*5
0.0 Hz
*3
No A A A A A 30AH
Mid
Frequency B
E1-12
Mid. output
frequency
voltage 2
0.0 to
255.0
*1
0.0 V
*3
No A A A A A 30BH
Mid Voltage
B
E1-13
Base voltage 0.0 to
255.0
*1
0.0 V
*4
No A A Q Q Q 30CH
Base Voltage
Inverter Class E1-01 Setting OV Detection Level
BTR Operation Level
∗
200 V Class All values Approx. 410 V Approx. 394 V
400 V Class
400 V or more Approx. 820 V Approx. 788 V
Less than 400 V Approx. 720 V Approx. 682 V