EasyManua.ls Logo

YASKAWA Varispeed G7 - Page 375

YASKAWA Varispeed G7
499 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
6-169
DI-08 Reference Ranges
When using the DI-08, the following ranges can be set depending on the settings of the constants.
2 to 39 -
12 bits 3-digit BCD with sign, 1 rpm -1599 to 1599 rpm 1 rpm
16 bits 4-digit BCD with sign, 1 rpm -15999 to 15999 rpm 1 rpm
X0040
to
X9999
(X = 0
to 3)
- 12 bits
3-digit BCD with sign, 100%/(1- to 4-
digit setting of o1-03)
-1599 to 1599
5th digit of o1-03 set-
ting:
X = 0, unit: 1
X = 1, unit: 0.1
X = 2, unit: 0.01
X = 3, unit: 0.001
- 16 bits
4-digit BCD with sign, 100%/(1- to 4-
digit setting of o1-03)
-9999 to 9999
(when o1-03 = 9999)
X1000
(X = 0
to 3)
- 16 bits 4-digit BCD with sign, 100%/10000 -1000 to 1000
F3-01 Reference Input Mode Reference Setting Range
U1-01 Monitor Unit
o1-03 = 0 o1-03 = 1
0 2-digit BCD with sign, 1% -110 to 110%
0.01 Hz 0.01%
1 2-digit BCD with sign, 0.1% -15.9 to 15.9%
2 2-digit BCD with sign, 0.01% -1.59 to 1.59%
3 2-digit BCD with sign, 1 Hz -159 to 159 Hz
4 2-digit BCD with sign, 0.1 Hz -15.9 to 15.9 Hz
5 2-digit BCD with sign, 0.01 Hz -1.59 to 1.59 Hz
6-
7 8-bit binary with sign, 100%/255 -255 to 255
o1-03 F3-01
Switch
S1
Reference Input Mode
Reference Setting
Range
U1-01 Monitor Unit
o1-03 = 0 o1-03 = 1

Table of Contents