Specifications of Options and Peripheral Devices
9-9
* 1. Under development.
* 2. Applicable for G7-Series Inverters with software versions PRG: S1038 or later
Built-in
(con-
nected
to con-
nector)
Com-
muni-
cations
Option
Boards
DeviceNet
Communica-
tions Inter-
face Board
SI-N
73600-
C021X
Used to communicate with an Inverter from a host computer
using DeviceNet communications to start/stop Inverter opera-
tion, read/set parameters, and read/set monitor constants (out-
put frequencies, output currents, etc.).
-
ProfiBus-DP
Communica-
tions Inter-
face Board
SI-P
73600-
C022X
Used to communicate with an Inverter from a host computer
using ProfiBus-DP communications to start/stop Inverter
operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
-
ProfiBus-DP
Communica-
tions Inter-
face Board
SI-P1
73600-
C033X
InterBus-S
Communica-
tions Inter-
face Board
SI-R
*1
Used to communicate with an Inverter from a host computer
using InterBus-S communications to start/stop Inverter opera-
tion, read/set parameters, and read/set monitor constants (out-
put frequencies, output currents, etc.).
-
CANopen
Communica-
tions Inter-
face Board
SI-S1
*1
Used to communicate with an Inverter from a host computer
using CANopen communications to start/stop Inverter opera-
tion, read/set parameters, and read/set monitor constants (out-
put frequencies, output currents, etc.).
-
ControlNet
Communica-
tions Inter-
face Board
SI-U
*1
Used to communicate with an Inverter from a host computer
using ControlNet communications to start/stop Inverter opera-
tion, read/set parameters, and read/set monitor constants (out-
put frequencies, output currents, etc.).
-
CC-Link
Communica-
tions Inter-
face Board
SI-C
73600-
C032X
Used to communicate with an Inverter from a host computer
using CC-Link communications to start/stop Inverter opera-
tion, read/set parameters, and read/set monitor constants (out-
put frequencies, output currents, etc.).
-
L
ONWORKS
Communica-
tions Inter-
face Board
SI-J
73600-
C035X
Used to communicate with an Inverter from a host computer
using L
ONWORKS communications to start/stop Inverter
operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
-
L
ONWORKS
Communica-
tions Inter-
face Board
SI-W1
73600-
C034X
Used to communicate with an Inverter from a host computer
using L
ONWORKS communications to start/stop Inverter
operation, read/set parameters, and read/set monitor constants
(output frequencies, output currents, etc.).
With Display Data Channel (DDC) function.
-
MECHA-
TROLINK-
Communi-
cations Inter-
face Board
SI-T
*2
100-017-994
Used to communicate with an Inverter from a host computer
using MECHATROLINK communications to start/stop
Inverter operation, read/set parameters, and read/set monitor
constants (output frequencies, output currents, etc.).
-
Table 9.5 Option Boards (Continued)
Type Name
Code Num-
ber
Function
Document
Number

Table of Contents

Other manuals for YASKAWA Varispeed G7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 and is the answer not in the manual?

YASKAWA Varispeed G7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7
CategoryInverter
LanguageEnglish

Related product manuals