June 2006 Preface
Addition:
Safety Precautions
• Setting User Constants
Stationary autotuning precautions
•
Trial Operation
Inverter settings precautions
•
Maintenance and Inspection
Precaution about using an Inverter with an elevator
Precaution about times when a holding brake is necessary
Chapter 1 Revision: Fig1.9 Removing the Terminal Cover (Model CIMR-G7A23P7 Shown Above)
Chapter 2
Addition:
•
Note in Table 2.4 Main Circuit Terminal Functions
•
IMPORTANT 12, 13, and 14 in Connection Diagram
•
IMPORTANT in Standard Connection Diagrams
•
Table 2.14 Option Board Specifications
MECHATROLINK Communication Board
• Fig 2.22 Cutting the Front Cover
Revision:
•
IMPORTANT 2 in Connection Diagram
•
Factory setting for multi-function photo-coupler output 4 frequency detection 2 →
minor fault
•
Table 2.2 400 V Class Wire Sizes
Following recommended wire sizes:G7A4185, G7A4220, G7A4300
•
Description of installing a ground fault interrupter in Wiring the Main Circuits
•
Fig 2.24 Wiring an Open-collector Input
Chapter 4
Addition:
•
Precautions for precision settings
•
Description of stationary autotuning 2
Revision:
•
Fig 4.1 Trial Operation Flowchart
•
Fig 4.3 Settings According to the Control Method
• Checking Operating Status under
Loaded Operation
Chapter 5
Addition:
•
Following constants
b3-17, b3-18, b3-19, F6-08, F6-09, H5-10, L8-32, L8-39, L8-41, U1-61, U1-63, U1-83,
U1-84, U2-21, U2-22, o2-18, T1-09
•
2 setting of b1-08
•
4 setting of T1-01
•
Note in the table of L2 constants
•
Note *2 in the table of U2 constants
•
2F, 36, and 3D settings of multi-function output terminal
• Note *5 about C4-02 in the table in
Factory Settings that Change with the Control
Method
(
A1-02)
•
L8-39 in the table in Factory Settings that Change with the Inverter Capacity (o2-04)
Revision:
•
Note *2 about E2-01
•
No
te *
3 about E2-03 and E4-03
•
Note *8 about T1-09
Chapter 6
Addition:
•
Inputting Master Speed Frequency Reference Only (Current Input) in Frequency
Reference
•
Following items in Continuing Operation
• IMPORTANT in Speed Search
• Additional description of master speed analog input in Continuing Operation at
Constant Speed When Frequency Reference Is Lost
•
Varispeed F7 Function Block
• Frequency Detection 5 in
Using Frequency Detection
•
Setting the V/f Pattern
Description about the changes in the OV and BTR levels that depend on the input volt-
age in Setting the V/f Pattern.
•
Torque Control
Description of setting speed limit bias
•
Comparing Inverter Constants and Digital Operator Constant Set Values (VERIFY)
under Digital Operator Functions
Description of error display CPE
•
Using Inverters for Elevating Machines
• Description about frequency detection 5, which is an Inverter output signal to engage
a holding brake
• IMPORTANT about precautions on trial operation
• IMPORTANT in Brake ON/OFF Sequence
•
Current Alarm Function
•
Peak Hold Current Monitoring Function
•
Maintenance Timer Display Function
Date of
Publication
Rev.
No.
Section Revised Content