Configuring Security Features
189
Disabled
Fail to establish a call
RTP Call
RTP Call
When H.235 is enabled on both endpoints, calls will be encrypted, and the lock icon
appears on the display device of each endpoint during a call..
To configure H.235 via the web user interface:
1. Click on Account->H323.
2. Select the desired value from the pull-down list of H.235 Encryption.
3. Click Confirm to accept the change.
VoIP phones often suffer from network attacks in public network, which results in
communication failure. To ensure the safety of the enterprise VoIP phone, you can
configure abnormal call answering feature for handling abnormal calls using the SIP
protocol. For abnormal calls using the H.323 protocol, you can configure safe mode call
feature to handle them.

Table of Contents

Other manuals for Yealink VC110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink VC110 and is the answer not in the manual?

Yealink VC110 Specifications

General IconGeneral
Digital zoom4 x
Focus adjustmentAuto
Video codecsH.264, H.263
Maximum frame rate30 fps
Supported video modes720p, 1080p
Video formats supportedH.263, H.264
Supported graphics resolutions352 x 288, 704 x 576, 1280 x 720 (HD 720), 1920 x 1080 (HD 1080)
Voice codecsG.711a, G.722, G.722.1, G.722.1C
Line-inYes
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Pan range-100 - 100 °
Tilt angle range-30 - 30 °
Security algorithms128-bit AES, HTTPS, SRTP, SSL/TLS
Ethernet LAN data rates10, 100 Mbit/s
Supported network protocolsTCP/IP (IPv4), DHCP/ stastic IP, HTTP/ HTTPS, SRTP/TLS, IEEE802.1X, LLDP-MED, VLAN
Current2 A
Power consumption (max)30 W
Power consumption (typical)24 W
Storage temperature (T-T)-20 - 50 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)10 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth151.5 mm
Width234.6 mm
Height161 mm
Package depth318 mm
Package width432 mm
Package height274 mm
Package weight5900 g