Administrator‘s Guide for Yealink VC110 Video Conferencing Endpoint
76
The following tables identify the number of ports required per connection by protocol
and the type of call.
Required ports for an H.323 two-way call:
8 UDP ports (6 if presentation is disabled)
2 TCP ports
Required ports for a SIP two-way call:
8 UDP ports (6 if presentation is disabled)
The following table lists the number of UDP and TCP ports needed for the video
conferencing endpoint. This information can help you to determine the range of port
number to be entered in the Reserved Port field.
Required Ports for an
H.323 Call
Required Ports for a
SIP Call
Two-way video call and
a presentation and an
audio call
Parameters for reserved ports on the endpoint are described below:
Configures the range of the UDP
ports.
Valid values: 1-65535
Default range: 50000-50499
Note: SIP and H.323 calls share
the configured ports.
If you change this parameter, the
endpoint will reboot to make the
change take effect.
Remote Control
Web User Interface
Configures the range of the TCP
ports.
Valid values: 1-65535
Default range: 50000-50499
Note: SIP and H.323 calls share
Remote Control