5-127
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:LOGic:PODA_PODB:SIZE
Function Sets or queries the logic signal’s display size of
logic input ports A and B.
Syntax
:LOGic:PODA_PODB:SIZE {LARGe|
MIDium|SMALl}
:LOGic:PODA_PODB:SIZE?
Example
:LOGIC:PODA_PODB:SIZE LARGE
:LOGIC:PODA_PODB:SIZE?
-> :LOGIC:PODA_PODB:SIZE LARGE
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe?
Function Queries all state display settings of logic input
ports A and B.
Syntax
:LOGic:PODA_PODB:STATe?
Example
:LOGIC:PODA_PODB:STATE?
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe:ASSignment?
Function Queries state display assignments of logic input
ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:ASSignment?
Example
:LOGIC:PODA_PODB:STATE:ASSIGNMENT?
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_
PODB:STATe:ASSignment:ALL
Function Sets the state display assignments of all bits of
logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:ASSignment:AL
L {<Boolean>}
Example
:LOGIC:PODA_
PODB:STATE:ASSIGNMENT:ALL ON
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_
PODB:STATe:ASSignment<x>:BIT
Function Sets or queries the display assignments of all bits
of logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:
ASSignment<x>:BIT {<Boolean>}
:LOGic:PODA_PODB:STATe:
ASSignment<x>:BIT?
Example
:LOGIC:PODA_PODB:STATE1:ASSIGNMENT:
BIT ON
:LOGIC:PODA_PODB:STATE1:ASSIGNMENT:
BIT?
-> :LOGIC:PODA_PODB:STATE1:
ASSIGNMENT:BIT 1
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_
PODB:STATe:ASSignment:BUS2
Function Sets or queries the state display assignment bus
setting of logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:ASSignment:
BUS2 {<Boolean>}
:LOGic:PODA_PODB:STATe:ASSignment:
BUS2?
Example
:LOGIC:PODA_PODB:STATE:ASSIGNMENT:
BUS2 ON
:LOGIC:PODA_PODB:STATE:ASSIGNMENT:
BUS2?
-> :LOGIC:PODA_PODB:STATE:
ASSIGNMENT:BUS2 1
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_
PODB:STATe:ASSignment:BUS3
Function Sets or queries the state display assignment bus
setting of logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:ASSignment:
BUS3 {<Boolean>}
:LOGic:PODA_PODB:STATe:ASSignment:
BUS3?
Example
:LOGIC:PODA_PODB:STATE:ASSIGNMENT:
BUS3 ON
:LOGIC:PODA_PODB:STATE:ASSIGNMENT:
BUS3?
-> :LOGIC:PODA_PODB:STATE:
ASSIGNMENT:BUS3 1
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe:CLOCk
Function Sets or queries the state display reference clock
waveform of logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:CLOCk {<NRf>|
BIT<x>}:
LOGic:PODA_PODB:STATe:CLOCk?
<NRf> = 1 to 3 (8 ch model:<NRf> = 5 to 7)
<x> = 0 to 7
Example
:LOGIC:PODA_PODB:STATE:CLOCK <NRF>
:LOGIC:PODA_PODB:STATE:CLOCK?
-> :LOGIC:PODA_PODB:STATE:
CLOCK <NRF>
Description An error will occur if 16 bit input (/L16 option) is
not supported.