Page #161 background imageLoading...
Page #161 background image
5-128
IM DLM4038-17EN
:LOGic:PODA_PODB:STATe:HYSTeresis
Function Sets or queries the hysteresis of the state display
reference clock waveform of logic input ports A
and B.
Syntax
:LOGic:PODA_PODB:STATe:
HYSTeresis {<NRf>}
:LOGic:PODA_PODB:STATe:HYSTeresis?
<NRf> = 0 to 4div (in 0.1-div steps)
Example
:LOGIC:PODA_PODB:STATE:HYSTERESIS 0
:LOGIC:PODA_PODB:STATE:HYSTERESIS?
-> :LOGIC:PODA_PODB:STATE:
HYSTERESIS 0
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe:MODE
Function Sets or queries the state display on/off status of a
bus of logic input ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:
MODE {<Boolean>}
:LOGic:PODA_PODB:STATe:MODE?
Example
:LOGIC:PODA_PODB:STATE:MODE ON
:LOGIC:PODA_PODB:STATE:MODE?
-> :LOGIC:PODA_PODB:STATE:MODE 1
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe:POLarity
Function Sets or queries the polarity of the state display
reference clock waveform of logic input ports A
and B.
Syntax
:LOGic:PODA_PODB:STATe:POLarity {RIS
E|FALL|BOTH}
:LOGic:PODA_PODB:STATe:POLarity?
Example
:LOGIC:PODA_PODB:STATE:POLARITY RISE
:LOGIC:PODA_PODB:STATE:POLARITY?
-> :LOGIC:PODA_PODB:STATE:
POLARITY RISE
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODA_PODB:STATe:THReshold
Function Sets or queries the detection level of the state
display reference clock waveform of logic input
ports A and B.
Syntax
:LOGic:PODA_PODB:STATe:
THReshold {<NRf>}
:LOGic:PODA_PODB:STATe:THReshold?
<NRf> = See the DLM4000 Features Guide for
this information.
Example
:LOGIC:PODA_PODB:STATE:
THRESHOLD <NRF>
:LOGIC:PODA_PODB:STATE:THRESHOLD?
-> :LOGIC:PODA_PODB:STATE:
THRESHOLD <NRF>
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODB?
Function Queries all settings of logic input port B.
Syntax
:LOGic:PODB?
Example
:LOGIC:PODB?
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODB:ALL?
Function Queries all bit settings of logic input port B.
Syntax
:LOGic:PODB:ALL?
Example :LOGIC:PODB:ALL? Description An error
will occur if 16 bit input (/L16 option) is not
supported.
:LOGic:PODB:ALL:DISPlay
Function Turns on or off all bit displays of logic input port B.
Syntax
:LOGic:PODB:ALL:DISPlay {<Boolean>}
Example
:LOGIC:PODB:ALL:DISPLAY ON
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODB:ALL:LEVel
Function Sets the user-defined threshold level for logic
input port B.
Syntax
:LOGic:PODB:ALL:LEVel {<Voltage>}
:LOGic:PODB:ALL:LEVel?
<Voltage> = −10 to 10 V (in 0.1-V steps)
Example
:LOGIC:PODB:ALL:LEVEL−10
:LOGIC:PODB:ALL:LEVEL?
->:LOGIC:PODB:ALL:LEVEL−10
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODB:ALL:TYPE
Function Selects the threshold level for logic input port B.
Syntax
:LOGic:PODB:ALL:TYPE {CMOS1|CMOS2|
CMOS3|CMOS5|ECL}
:LOGic:PODB:ALL:TYPE?
Example
:LOGIC:PODB:ALL:TYPE CMOS1
:LOGIC:PODB:ALL:TYPE?
-> :LOGIC:PODB:ALL:TYPE CMOS1
Description An error will occur if 16 bit input (/L16 option) is
not supported.
:LOGic:PODB:BIT<x>?
Function Queries all settings of a bit of logic input port B.
Syntax
:LOGic:PODB:BIT<x>?
<x> = 0 to 7
Example
:LOGIC:PODB:BIT1?
Description An error will occur if 16 bit input (/L16 option) is
not supported.
5.19 LOGic Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals