5-172
IM DLM4038-17EN
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:RTR
Function Sets or queries the RTR value, which is one
of the ID and data conditions, for CAN FD bus
signal searching.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:RTR {<Boolean>}
:SERialbus<x>:CANFD:SEARch:SETup[:ID
Data]:RTR?
<x> = 1 to 4
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:IDDAT
A:RTR ON
:SERIALBUS1:CANFD:SEARCH:SETUP:IDDAT
A:RTR?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:ID
DATA:RTR 1
:SERialbus<x>:CANFD:SEARch:SETup:MO
DE
Function Sets or queries the CAN FD bus signal search
mode setting.
Syntax
:SERialbus<x>:CANFD:SEARch:SETup:MO
DE {EFRame|ESI|FDF|IDData|SOF}
:SERialbus<x>:CANFD:SEARch:SETup:MO
DE?
<x> = 1 to 4
Example
:SERIALBUS1:CANFD:SEARCH:SETUP:MO
DE EFRAME
:SERIALBUS1:CANFD:SEARCH:SETUP:MODE?
-> :SERIALBUS1:CANFD:SEARCH:SETUP:MO
DE EFRAME
:SERialbus<x>:CXPI?
Function Queries all CXPI bus signal analysis and search
settings.
Syntax
:SERialbus<x>:CXPI?
<x> = 1 to 4
:SERialbus<x>:CXPI:ANALyze?
Function Queries all CXPI bus signal analysis settings.
Syntax
:SERialbus<x>:CXPI:ANALyze?
<x> = 1 to 4
:SERialbus<x>:CXPI[:ANALyze]:SETup?
Function Queries all CXPI bus signal analysis bus settings.
Syntax
:SERialbus<x>:CXPI[:ANALyze]:SETup?
<x> = 1 to 4
:SERialbus<x>:CXPI[:ANALyze]:SETup:B
RATe
Function Sets or queries the CXPI bus signal analysis bit
rate (data transfer rate).
Syntax
:SERialbus<x>:CXPI[:ANALyze]:SETup:
BRATe {<NRf>|USER,<NRf>}
:SERialbus<x>:CXPI[:ANALyze]:SETup:
BRATe?
<x> = 1 to 4
<NRf> = 4800, 9600, 19200
USER <NRf> = 4000 to 50000
Example
:SERIALBUS1:CXPI:ANALYZE:SETUP:
BRATE 19200
:SERIALBUS1:CXPI:ANALYZE:SETUP:
BRATE?
-> :SERIALBUS1:CXPI:ANALYZE:SETUP:
BRATE 19200
:SERialbus<x>:CXPI[:ANALyze]:SETup:C
EDetection
Function Sets or queries the enable/disable condition
of counter error detection for CXPI bus signal
analysis.
Syntax
:SERialbus<x>:CXPI[:ANALyze]:SETup:
CEDetection {<Boolean>}
:SERialbus<x>:CXPI[:ANALyze]:SETup:
CEDetection?
<x> = 1 to 4
Example
:SERIALBUS1:CXPI:ANALYZE:SETUP:
CEDETECTION ON
:SERIALBUS1:CXPI:ANALYZE:SETUP:
CEDETECTION?
-> :SERIALBUS1:CXPI:ANALYZE:SETUP:
CEDETECTION 1
:SERialbus<x>:CXPI[:ANALyze]:SETup:C
TOLerance
Function Sets or queries the CXPI bus signal analysis
clock tolerance.
Syntax
:SERialbus<x>:CXPI[:ANALyze]:SETup:
CTOLerance {<NRf>}
:SERialbus<x>:CXPI[:ANALyze]:SETup:
CTOLerance?
<x> = 1 to 4
<NRf> = ±0.5% to ±10.0% (resolution: 0.1%)
Example
:SERIALBUS1:CXPI:ANALYZE:SETUP:
CTOLERANCE 5
:SERIALBUS1:CXPI:ANALYZE:SETUP:
CTOLERANCE?
-> :SERIALBUS1:CXPI:ANALYZE:SETUP:
CTOLERANCE 5.00E+00
5.25 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM4038