Page #240 background imageLoading...
Page #240 background image
5-207
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:SERialbus<x>:RWINdow
Function Sets or queries in which zoom window, ZOOM1
or ZOOM2, the detected section will be displayed.
Syntax
:SERialbus<x>:RWINdow {Z1|Z2}
:SERialbus<x>:RWINdow?
<x> = 1 to 4
Example
:SERIALBUS1:RWINDOW Z1
:SERIALBUS1:RWINDOW?
-> :SERIALBUS1:RWINDOW Z1
:SERialbus<x>:SENT?
Function Queries all SENT signal analysis and search
settings.
Syntax
:SERialbus<x>:SENT?
<x> = 1 to 4
:SERialbus<x>:SENT:ANALyze?
Function Queries all SENT signal analysis settings.
Syntax
:SERialbus<x>:SENT:ANALyze?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup?
Function Queries all bus setup settings for SENT signal
analysis.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:D
ISPlay
Function Sets or queries the display mode for the SENT
signal analysis result.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:D
ISPlay {BOTH|FAST|SLOW}
:SERialbus<x>:SENT[:ANALyze]:SETup:D
ISPlay?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:DISPL
AY BOTH
:SERIALBUS1:SENT:ANALYZE:SETUP:DISPL
AY?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:DI
SPLAY BOTH
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST?
Function Queries all SENT signal analysis fast channel
settings.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:DTYPe
Function Sets or queries the SENT signal analysis fast
channel data format.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:DTYPe {NIBBle|USER}
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:DTYPe?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:
DTYPE NIBBLE
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:
DTYPE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FA
ST:DTYPE NIBBLE
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup?
Function Queries all settings related to fast channel user-
defined data of SENT signal analysis.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>?
Function Queries all settings related to the specified user-
defined data of the SENT signal analysis fast
channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:MODE
Function Sets or queries the enable/disable condition
of the specified user-defined data of the SENT
signal analysis fast channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:MODE {<Boolean>}
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:MODE?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:
USETUP:DATA1:MODE ON
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:
USETUP:DATA1:MODE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FA
ST:USETUP:DATA1:MODE 1
5.25 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals