ProFace X (DS) User Manual
Page | 73 Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Access Control Options 11.1
Tap Access Control Options on the Access Control interface to set the parameters of the control lock of
the terminal and related equipment.
Function Description
Function Name Description
Gate Control Mode
It toggles between ON or OFF switch to get into the gate control mode or
not.
When set to ON, the interface removes the Door lock relay, Door sensor relay,
and Door sensor type options.
Door Lock Delay (s)
The length of time that the device controls the electric lock to be in unlock
state.
Valid value: 1 to 99 seconds; 0 seconds represents disabling the function.
Door Sensor Delay (s)
If the door is not locked and is left open for a certain duration (Door Sensor Delay),
an alarm will be triggered.
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three types of Sensors: None, Normal Open (NO), and Normal Closed
(NC).
None: It means the door sensor is not in use.
Normally Open (NO): It means the door is always left open when the electric
power is on.
Normally Closed (NC): It means the door is always left closed when the electric
power is on.