Setting Explanation
Int Free Run Internal timecode will be generated regardless of the recording
mode.
The internal timecode can be set manually using the following
operations:
Jamming internal timecode
Restarting internal timecode with a specified value
Timecode will always be output from the TIMECODE OUT jack.
Int Record Run Internal timecode will be generated only when recording.
The internal timecode can be set manually using the following
operations:
Jamming internal timecode
Restarting internal timecode with a specified value
When switching from another mode, or when recording stops, the
internal timecode will stop at the last value.
Int RTC Run Internal timecode will be generated regardless of the recording
mode.
In the following situations, the internal timecode will be synchronized
(jammed) with the RTC (internal clock):
At startup
When “Date/Time (RTC)” has changed (→Setting the date and time
(Date/Time (RTC)))
When switching to this timecode mode
Timecode will always be output from the TIMECODE OUT jack.
Ext The internal timecode will chase the external timecode.
You can also enable the automatic generation of internal timecode
when there is no external timecode. (→Automatically enabling
internal timecode when no external timecode is input)
Ext Auto Rec The internal timecode will chase the external timecode.
You can also enable the automatic generation of internal timecode
when there is no external timecode. (→Automatically enabling
internal timecode when no external timecode is input)
Recording starts automatically when external timecode input is
detected. Recording stops automatically when external timecode
stops.