Installation
120
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Maximum line length for a wire diameter of 0,5 mm: 820 m
Maximum line length for a wire diameter of 0,6 mm: 1170 m
Example 3:
Evaluation of an existing line installation
Line diameter: 0.5 mm
Loop resistance: 120
Fig. 43 indicates:
•Line length: 660m
Power available: 2120 mW
Cable Requirements
Tab. 53 Requirements for an DSI bus cable
Installation rules
If an Aastra DECT radio unit is used, do not connect any other system phone to
the same DSI bus.
Do not use any terminating resistors at the bus extremity.
Avoid using different cable cross-sections on the same bus
Use the supplied cables for connecting the system phones
Cabling of AD2 terminals is restricted to pairs of a separate dedicated cable(s).
1)
.
Core pairs cores 1 2 o 1 4
Stranded yes
1)
1)
Note: max. 25 m can be crossed unstranded.
(CH: Applies also to cable type G51)
Wire diameter, core 0.4…0.6 mm
Screening recommended
Characteristic impedance < 130 (1 MHz)
1)
Applies in Australia only