EasyManua.ls Logo

Aastra 415 - Design of Interface Cards, Modules and Wiring Adapters

Aastra 415
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Annex
249
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Tab. 121 Electrical isolation of interfaces
Tab. 122 Ambient conditions
Tab. 123 Electrical data
Tab. 124 Heat dissipation
7. 4. 4 Design of interface cards, modules and wiring adapters
Tab. 125 Design
Interface Aastra 415/430
Analogue network interfaces 0.2 kV Operating isolation
Digital network interfaces BRI Operating isolation
Control input on ODAB no isolation, but input impedance > 8 k
Freely connectable relay contacts on ODAB 0.2 kV
Door intercom interface on ODAB 0.2 kV
Control input on FXS interface no isolation
Control output on FXS interface no isolation
Audio input no isolation
Condition Aastra 415/430
Ambient temperature 5 °C to 45 °C
Relative air humidity 30 % to 80 %, non-condensating
Aastra 415 Aastra 430
Class of protection 1
Input voltage 95 V…253 V, 48…62 Hz
Input current approx. 0.11 A...0.7 A approx. 0.11 A...1.0 A
Resistant to voltage breaks < 6ms
Power input with min. configuration approx. 15 W approx. 15 W
Power input with max. configuration approx. 50 W approx. 75 W
Undervoltage limit
(system reset, data backup)
< 90 V
Aastra 415 Aastra 430
Maximally configured system approx. 37 W = 135 kJ/h approx. 50 W = 180 kJ/h
Card/module Design
TIC-4TS B
TIC-2TS B
ESST C
TIC-4AB B
TIC-2AB B
TIC-1PRI C
EAAB2 B