Installation
82
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
4. 2. 4 Safety regulations
Be sure to observe the following safety regulations before carrying out work inside 
a communication server:
Warning
Components, interface cards or system modules can be damaged by 
electrical voltage.
Always disconnect the communication server from the power supply 
before removing the housing cover.
Warning
Components can be damaged by electrostatic discharge when touched. 
Always touch the earthed metal case of the communication server before 
carrying out work inside the housing. This also applies to interface cards 
and system modules that are no longer packed inside the ESD protective 
wrapping.
4. 2. 5 Wall mounting
There are two possibilities for wall mounting. In the first variant the front panel 
faces right (see Fig. 12); in the second, it faces downwards (see Fig. 13). The wall-
mounting option chosen will depend on the way the cables are routed. The LED 
display remains visible whatever the mounting position, even when the cable 
cover is fitted.
Warning
A wall-mounting option in which the front panel faces upwards or to the 
right is not permitted. Inadequate heat dissipation can damage the com-
munication server.
4. 2. 5. 1 Minimum distances
To ensure adequate heat dissipation, minimum distances need to be maintained 
with other objects such as cable ducts, cabinets or mobile objects. Maintaining 
minimum distances also allows the installation of the cable cover and the possibil-
ity of suspending the communication server into and out of the wall-mounted 
screws.
The two diagrams below illustrate the two wall-mounting possibilities.