Annex
247
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
7. 4 Technical data
7. 4. 1 Network interfaces
The following technical data applies to the network interfaces:
Basic rate interface BRI-T
Standard Euro ISDN interface as per CTR-3
Configurable for point-to-point or point-to-multipoint operation
Analogue network interfaces
Voice path with A/D and D/A conversion (standard PCM, A-law)
Transmission as per ES 201 168 (level country-specific)
•Signalling as per TBR 21
Pulse or DTMF dialling, Flash signal
•Loop current detection
Call charge receive 12 or 16 kHz (frequency and level setting country-specific)
CLIP detection in accordance with ETS 300 778-1
7. 4. 2 Terminal interfaces
The following technical data applies to the terminal interfaces:
Digital terminal interface DSI
Proprietary interface, two-wire
Two system phones of the Aastra 5300 series can be connected per interface
(AD2 protocol)
1)
One SB-4+/SB-8 radio unit can be connected (with 8 channels the SB-8 radio
units requires two DSI interfaces)
Power supply min. 75 mA, limiting at approx. 80 mA, terminal voltage 36…48 V
Line termination in the phone
Transparent transmission of 2 PCM channels
1)
Office 10, Office 25, Office 35, Office 45/45pro are supported as before