Annex
248
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Digital terminal interface BRI-S
•Standard Euro ISDN interface
• Phantom power supply min. 140 mA, limiting at approx. 170 mA, terminal volt-
age 36…41 V
• Up to 8 terminals can be connected
• Maximum of 2 simultaneous call connections
Analogue terminal interface FXS
• Configurable multifunctional interface for connecting analogue terminals and 
equipment.
• The following applies for the FXS mode Phone / Fax, two-wire door and general 
bell:
– Voice path with A/D and D/A conversion (standard PCM, A-law)
– Transmission as per ES 201 168 (level country-specific)
– Constant-current loop supply approx. 25 mA (with loop resistance  1000 )
– Receive pulse or DTMF dialling
– CLIP display on all analogue terminal interfaces (only on 2 analogue terminals 
simultaneously).
– Ringing supply 40…43 V 50 Hz at load 4k; no DC voltage overlay (country-
specific versions also with 25 Hz)
– No control key detection
– No charge signalling pulses
• For more technical details and cable requirements see "Multifunctional FXS in-
terfaces", page 127.
7. 4. 3 Communication server
Tab. 120 Dimensions and weights 
 Aastra 415/430 for wall 
mounting
 Aastra 415/430 in rack 
mounting
Height 65 mm 65 mm
Width 360 mm 483 mm
Depth 294mm 294mm
Weight (excl. mains cord, interfaces cards, modules 
and packaging)
2.4 kg 2.5 kg