Operation and Maintenance
216
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
 The first start is initiated once the key is released.
 The system now deletes the database. This is indicated with Pattern [19]. 
Thereafter, the system changes to Normal Mode after a brief interruption. It now 
still remains up to five minutes until the communication server is accessible with 
WebAdmin.
Tab. 99 Patterns while the database is deleted as a result of a first start
Tip:
You can also initiate a first start of the communication server via 
WebAdmin in the Maintenance / System reset ( =4e) view. There you can 
also reset the sales channel in addition to a first start.
6. 4. 4. 7 Resetting the IP address
The IP address data is stored on the EIM card and is retained even after a first start. 
The following sequence only resets the IP address data of the communication 
server to the default values. All the other data is retained.
Requirement: 
The system is in "Boot Command Mode", page 209.
1. Press the pilot key several times with a short keypress (SC) until "F2" lights up 
red.
2. Press the pilot key with a long keypress (LC)
 After 2 second keypress "F2" lights up green by way of confirmation.
 The IP address data is reset to the default values once the key is released. The 
startup then continues normally.
Default values of the IP address data:
• IP address: 192.168.104.13
• Subnet mask: 255.255.255.0
• Gateway: 0.0.0.0
Pattern 
No.
F0 F1 F2 F3 F4 SYS
Dura-
tion [s]
Meaning
[19] ~5 Deleting the database