EasyManua.ls Logo

Aastra 415 - Page 128

Aastra 415
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
128
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Fig. 53 Connection for FXS mode: Phone/fax
The no-load voltage at the ports is approx.53 VDC. The loop current is limited to 25
Am.
Tab. 60 Cable requirements for FXS mode: Phone/fax
FXS mode: 2-wire door
In this mode 2-wire door intercoms with DTMF control functions can be connected.
The no-load voltage in this mode is 24 VDC. The loop current is limited to 25 mA.
Fig. 54 Connection for FXS mode: 2-wire door
All ports
Core pairs cores 1 2
Stranded only with lengths > 200 m
Wire diameter, core 0.4 … 0.8 mm
FXS resistance max. 2 625
Line length 0.6 mm diameter max. 10 km
Screening not required
a
b
FXS interface
a
b
FXS interface