Installation
134
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Connection
The EFOP fan-out-panel comprises 5 connection blocks of 10 RJ45 sockets each.
The line switchover is carried out on the two left-hand connection blocks. The
three right-hand connection blocks are used for separating the four-fold assigned
RJ45 sockets FXS1-4 and FXO1-4. The unassigned connection blocks can be used
for other purposes.
The diagram below shows the connection between an EFOP fan-out-panel and 4
emergency phones and 4 analogue exchange lines.
Fig. 60 Connection of EFOP fan-out-panel (example)
The patch cables are available separately in lengths of 1 and 2 m (see "Equipment
Overview", page 245).
The internal wiring of the 3 connectors right is shown in the table below. The wir-
ing is shown for sockets 1 - 4. Sockets 5 - 8 are wired accordingly.