Installation
136
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Power supply
The EFOP fan-out-panel needs its own power supply and is powered by the sup-
plied power supply unit FSP065 via one of the two equivalent supply sockets. The
power supply unit is connected to the mains using a two-pin standard Euro power
cable.
Input values EFOP fan-out-panel 19 VDC / 0.5 A
Hazard:
Hazard due to heat generation in the event of short-circuits. The mains
power supply connection must be protected with 16 A maximum.
Please also note the following points:
The mains connector acts as a disconnecting device and must be positioned so
that it is easily accessible.
Original power supply units FSP065 (19 VDC / 3.42 A) are to be used exclusively.
The EFOP fan-out-panel is designed for installation in a 19” rack and must be fit-
ted in rack only.
Earthing
The EFOP fan-out-panel has 4 equivalent connections for the protective earthing
(see Fig. 61).
Warning
Because analogue trunk lines are to be routed via the fan-out panel EFOP,
for safety reasons the fan-out panel must be connected to the protective
earth.