Operation and Maintenance
242
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
The system status lines provide useful information for a more in-depth fault diag-
nosis. They can be printed out and sent to customer support on request.
Tab. 112 The displayed data and what it means
System failures menu item
Tab. 113 System failures display
The system's last 80 system failures (restarts) are displayed. The restarts are incre-
mented in the counter in the top right (0...255).
Significance of the display: Error type W = restart (watchdog), date, time
When printing, only the last 4 addresses are printed out.
Power failures menu item
Tab. 114 Power failures display
Only the restart time is recorded.
Display Description
Normal value/
idle state
Note
BCS: xxxxx Number of existing BCS references BCS: 00000 Each active connection needs 2
BCS references
CC: xxxxx Number of existing call controls CC: 00000 For each BCS reference there is
one or more CC
SUBS: xxxx Number of users in the system SUBS: 0000 0000: No ports busy
NSUB: xxxx Number of PISN users in the system NSUB: 0000 0000: No PISN user in the system
LINE: xxxx Number of lines in the system LINE: 0000 0000: No lines defined
DIST: xxxx Number of call distributions in the sys-
tem
DIST: 0000 0000: No call distribution defined
DDIN: xxxx Number of DDI numbers in the system DDIN: 0000 0000: No DDI numbers defined
ABB: xxxx Number of abbreviated dialling num-
bers in the system
ABB: 1000 1000: Default value unchanged
== SYSTEM FAILURES 52
W 15.09.10 13:32 011A59F2, 011A5A8C, 01156FFE
W 06/12/2010 13:32 011A59F7 011A5A82 01156FF1
== POWER FAILURES
01/12/2010 16:13