Program features 135
Pump cleaning
The Pump cleaning function can be used for preventing solids from building up on
pump impellers. The function consists of a programmable sequence of forward and
reverse runs of the pump (see the figure below), effectively shaking off any residue
on the impeller. This is especially useful with booster and wastewater pumps.
The pump cleaning cycle can be activated at start-up, with a user-defined period, with
a selectable digital input or by the Supervision function (for example triggered by the
motor input current).
Settings
Parameter Additional information
Group 46: Pump cleaning Pump cleaning settings
2205/2206 Acceleration time 2 / Deceleration time 2
t
Forward
Reverse
4607
Trigger
time
4602
Forward
step
Number of steps
4603
Reverse
step
4605
Forward
time
4605
Forward
time
4606
Reverse
time
4604
Off
time
4604
Off
time
4604
Off
time