Overview of power and control connections
The logical diagram below shows the power connections and control interfaces of the
drive.
Slot 2
L1
L2
L3
PE
U/T1
V/T2
W/T3
X13
M
3 ~
L1
L2
L3
PE
Slot 3
F
X
X
X
F
X
X
Slot 1
1
2
3
6
7
4
8
...
...
..........
..........
..........
..........
..........
..........
.....
.....
......
......
5
F
X
X
X208
X12
UDC+
UDC-
Analog and digital I/O extension modules, feedback interface modules and fieldbus com-
munication modules can be inserted into slots 1, 2 and 3.
1
2
3
Memory unit4
Connector for safety functions modules.5
See Default I/O diagram of the drive control unit (ZCU-1x) (page 131) and Connector
data (page 136).
6
Control panel7
du/dt, common mode or sine filter (optional). See Common mode, du/dt and sine fil-
ters (page 227).
8
32 Operation principle and hardware description