Loading...
Years from start-up
Component
121110987654321
Cooling
RMain cooling fan
RLCL filter module cooling fan
RCircuit board compartment cooling
fan
Batteries
RControl panel battery
RRControl unit battery
Connections and environment
RRRRRRRRRRRRRCabinet door filters (IP54)
PPPPPPPPPPPPPQuality of supply voltage
Spare parts
IIIIIIIIIIIIISpare parts
PPPPPPPPPPPPPReforming DC circuit capacitors
(spare modules and spare capa-
citors)
Inspections by user
IIIIIIIIIIIIIAir inlet and outlet meshes
(IP22/IP42)
IIIIIIIIIIIIITightness of terminals
IIIIIIIIIIIIIAmbient conditions (dustiness,
moisture, corrosion, temperature)
IIIIIIIIIIIIICleaning of heatsinks
Symbols
Inspection (visual inspection and maintenance action if needed)I
Performance of on/off-site work (commissioning, tests, measurements or other work)P
ReplacementR
Maintenance and component replacement intervals are based on the assumption that the
equipment is operated within the specified ratings and ambient conditions. ABB recommends
annual drive inspections to ensure the highest reliability and optimum performance.
Note: Long term operation near the specified maximum ratings or ambient conditions may
require shorter maintenance intervals for certain components. Consult your local ABB Service
representative for additional maintenance recommendations.
Cleaning the interior of the cabinet
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death, or
damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
154 Maintenance