II K 4-70
Overview of Software
ParNo. Parameter name and significance Min Max Default Unit
(1)
custom.
setting
Grp 7 Maintenance (continued)
7.15 Commis Ref 1
Commissioning reference value 1
Scaling:
Field current 0…100%= 0…4096
Torque 0…100%= 0…4096
Armature current 0…100%= 0…4096
Speed 0…max = 0…max rpm
-32768 32767 0 integer
7.16 Commis Ref 2
Commissioning reference value 2
Scaling:
Field current 0…100%= 0…4096
Torque 0…100%= 0…4096
Armature current 0…100%= 0…4096
Speed 0…max = 0…max rpm
-32768 32767 0 integer
7.17 Squarewave Per
Duration of cycle of the square-wave generator.
0.01 60.00 2.00 s
7.18
Signal
Squarewave Act
Actual value of the square-wave generator.
- - - integer
7.19
Signal
Pan Text Vers
Display of text version in the control panel
integer
7.20
Signal
CPU Load
Operating performance of CPU in %
%
7.21
Signal
Con-Board
Signal which Controller Board SDCS-CON-3 is in
use.
0 = CON-3A
1..15 = unused
16 = CON-3
- - - Text
(1) no chan