Loading...
Refitting the tubular and tilt unit (IRB 1300-7/1.4 and IRB 1300-12/1.4)
Use these procedures to refit the tubular and tilt unit for IRB 1300-7/1.4 and IRB
1300-12/1.4.
Checking the sealing set on the tilt unit (Foundry Plus)
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000002489
Check the sealing set on the tilt unit.
The sealing set includes an inner ring cover (A),
a radial sealing (B), an outer ring cover (C) and a
gasket (D).
Replace the damaged part as described below:
If the inner ring cover is damaged, proceed
to 3.
If the radial sealing is damaged, proceed
to 4.
If the outer ring cover is damaged, proceed
to 5.
If the gasket is damaged, proceed to 6.
2
xx2000002490
Remove the old inner ring cover and fit the new
one with two M3x8 countersunk screws.
3