Screw: M5x16 12.9 Lafre
2C2B/FC6.9 (4 pcs)
xx2000001601
Refit the screws and washers.
Note
Do not tighten the screws yet.
4
Refitting the axis-6 timing belt
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000001600
Install the timing belt to the pulleys and verify that
the belt runs correctly in the grooves of the pul-
leys.
2
Used belt: 85.7-91.6 HzMove the motor to achieve proper belt tension.3
New belt: 102-107 Hz
Use a sonic tension meter to measure the timing
belt tension.
4
If the timing belt tension does not meet the require-
ment, loosen the motor screws and readjust.
Tightening torque: 6 Nm
xx2000001599
Secure the motor with the screws.5
Continues on next page