InformationAction
xx1400001460
Pull the latch (A) to the left, and push the Remote
Service box out.
7
Refitting
Use this procedure to refit the Remote Service box.
Action
DANGER
Before commencing any work inside the cabinet, please observe the safety information
in section DANGER - Make sure that the main power has been switched off! on page 33.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit please read the safety information
in the section WARNING - The unit is sensitive to ESD! on page 34
2
Pull the latch to the left and push the Remote Service box in position on the mounting
bracket.
3
Refit the safety board unit and secure it with attachment screws.4
Reconnect all connectors to the Remote Service box, Ethernet switch and safety board.5
Refit the cabinet cover.6
Perform the function tests in section Function tests on page 118 to verify that the safety
features work properly.
7
Product manual - IRC5 Compact 183
3HAC047138-001 Revision: G
© Copyright 2009-2017 ABB. All rights reserved.
4 Repair
4.17 Replacement of Remote Service box
Continued