Operation Manual / Power2 340-H / Low-pressure stage
15 Gas piping (option) / 15.3 Removal and installation
© Copyright 2022 ABB. All rights reserved. HZTL4053_EN Rev.F March 2022
15.3 Removal and installation
15.3.1 Weight
Product Weight [kg]
Gas piping (Power2 340-H) 11
Table70: Weight
15.3.2 Removing gas piping
Only use textile lifting gear to lift the bellows.
Fig.47: Removing the bellows
u Loosen nuts (85004) and remove with Verbus Ripp® washers (85005) and screws (85003).
u Remove bellows (85001) with metal C-rings (85002/61007).
Page 116 / 122