8.4 Malfunctions when stopping
Runout noises
Possible causes Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated Clean
Bearing damaged Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table34: Malfunctions when stopping – Runout noises
Runout time too short
Possible causes Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated Clean
Bearing damaged Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table35: Malfunctions when stopping – Runout time too short