Operation Manual / Power2 340-H / Low-pressure stage
3 Removal and installation / 3.2 Removing the low-pressure stage
© Copyright 2022 ABB. All rights reserved. HZTL4053_EN Rev.F March 2022
If present:
u Unplug the plug to the speed sensor (86505) and secure the rolled-up cable (2 m) on the
low-pressure or high-pressure stage. This protects the plug from being crushed.
Depending on the version of the bracket(04), a pin(03) may have been inserted to ensure
the safe assembly of the low-pressure stage. Therefore always remove the low-pressure
stage from and install it on the bracket vertically.
Fig.12: Removing the low-pressure stage
1. Attach the lifting gear to the suspension eye and additionally loop it around the gas out-
let casing(61001).
2. Loosen and remove the fixing screws(01) and the fixing screws(05) on the sup-
port(61300).
3. Remove the low-pressure stage vertically.
4. Cover the oil connections(02) in the bracket(04) to protect them from dirt.
Page 32 / 122