EasyManua.ls Logo

ACD MAX Series - MAX TK Technical Specifications

ACD MAX Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAX_Kurzanleitung_Brief_Overview_V1.03_de_en 100 / 105
32.2 MAX TK
Chassis
External dimensions
1130 x 550 x 580 mm (H x W x D)
Loading area
500 x 440 mm (W x D)
Loadbearing capacity
Max. total weight 220 kg/max. weight per shelf 60 kg
Weight (without additional
equipment)
Approx. 105 kg
Standards/safety
DIN 4554; GS-approval, certificate No. Z1A030619506 001 et.al.
Installation parts
Charger
Mains voltage
230 V AC 50/60 Hz
Mains current
1.4 A
Charging voltage
24 V DC
Charging current
10 A
Operating temperature
-28 °C to 40 °C (humidity < 95%, not condensing)
Standards/safety
EN 60335-1; EN 60335-2-29; EN 55014-1: 2000 + A1:2001
Battery
Type
Maintenance-free AGM block battery for cyclical small traction
Voltage
12 V DC
Capacity
60 Ah
Service life
Approx. 400 discharging/charging cycles
Fuses
Type
Vehicle blade-type fuses 20 A/32 V and 30 A/32 V
General information
Available voltages
24 V DC
Output power DC at 25 °C (W)
400 VA
Battery operating time at -28 °C
Approx. 8 hours at a load of 50 VA
Operating temperature
-28 °C to 40 °C (humidity < 95% not condensing)
Standards/safety
EN 60439-1/Section 8.3
(The right to make technical modifications is reserved)