EasyManua.ls Logo

ACD MAX Series - Troubleshooting Specific Version Issues; TK Version Charging Issues; MAX Li-Ion Not Functioning After Switching On

ACD MAX Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAX_Kurzanleitung_Brief_Overview_V1.03_de_en 93 / 105
30.4 TK version unit does not function during charging
Possible cause
Remedies
Plug of the 24 V DC input battery disconnected
Check plug on the rear panel
Fuses tripped
Check fuse on the rear panel or on the battery
Battery deeply discharged
Check battery charge status, if necessary charge
batteries or have customer services replace them
Charging LED flashes red
Charging LED flashes red: 2x short, 4x long
2x* short then 4x* long: charger temperature too
high or too low
Charging LED flashes red: 2x short 1x long
2x* short then 1x* long: max. charging period
exceeded
Charging LED flashes red: 2x short 2x long
2x* short then 2x* long: max. charging voltage too
high or too low
Charging LED flashes red: 2x short 3x long
2x* short then 3x* long: charging current too high
For a more detailed fault diagnosis of the charger, please see the battery charger manual.
30.5 MAX Li-Ion version unit does not function after switching on
Possible cause
Remedies
Battery plug of the 12 V DC input disconnected
Check battery plug behind the rear panel
Fuses tripped
Check fuses on the rear panel
Mobile workstation has automatically switched off
after a discharge of battery to < 10 %
Charge MAX Li-Ions. A charge of > 15 % must
follow after discharge down to an automatic switch-
off. Only then is it possible to switch on again.
Load on the socket strip too high
Check the output data of the load
Observe maximum load according to technical data

Table of Contents