Alarm input #2 - 0 = OFF, 1 = digital input is an alarm trigger input
(customer specific)
RS232 GPS 0=OFF 9600 / 1= ON 4800 GPS devices are in use
12.5.1.17 Camera Issue / Error
Indication whether an issue with a connected camera (e.g. no video signal) should be
classified as an error or not.
0 The malfunction of a camera is not classified as an error
1 The malfunction of a camera is classified as an error all USB-GPS
devices are automatically ignored.
12.5.1.18 APC/iCount Automatic Passenger Counter
iCount can be optionally bought as an addition to the device. You can display the
number of iCount devices used. A format must be selected otherwise the data is
automatically reset to the default value.
Figure 17) APC/ iCount
12.5.1.19 IBIS Integrated On- Board Information System
IBIS status query - status query with device number
IBIS time correction - RTC time correction, restart required
Figure 18) IBIS
12.5.1.20 Temperature Management
The hard drives are automatically shut down after exceeding or falling below the
temperature limits. Recording is stopped. The temperature limits are configurable.